Skip to main content
8205 Entrance/Office Mortise Lever Lock - Authorized Egress - Motor Drive - Fail Safe Satin Bronze

Roll over image to zoom in

ACSI M1510M-AE-1-8205-LNB-10-LC 8205 Entrance/Office Mortise Lever Lock - Authorized Egress - Motor Drive - Fail Safe Satin Bronze

Item #: M1510M-AE-1-8205-LNB-10-LC by ACSI

See reviewsSee reviews
In Stock

$954.46

/each
SAVE UP TO 95.45

Buying in bulk

QUICK SHIPPING*Usually ships in 1 business day
QTY
+
+ Add to Wishlist
Buy in Bulk & Save - See How Watch Now

Shop with Confidence

30 Days Easy Return. We are the largest supplier of the most adaptable, personalized hardware in the industry. We work hard to ensure you're satisfied with our products.

Features

Finish

Satin Bronze

Function

1510M AE-Fail Safe w/Authorized Egress

Cylinder Type

Conventional or IC

Finish Description

Satin Bronze

Product Type

Electronic Mortise Lock

Series

M1510M Series

Strike Size

4-7/8" x 3/32"

Minimum Stile Width

4-1/2 Inch

Manufacturer Parent

ACSI

Rose/Escutcheon Thickness

5/16 Inch

Handing

Reversible

Latch Throw

3/4 Inch

Function Description

Outside Trim is Locked When Power is Applied and Unlocked When Power is Removed (Storeroom Function When Energized); Lockset will Unlock in the Event of a Power Failure (Passage Function)

Electrified Features

12/24V at 250mA Inrush, 10mA Holding

Hand

Field Reversible

Grade

ANSI/BHMA Grade 1

Case Dimensions

7/64" Thick

Sub-Series

EAC_Electronic_Mortise_Locks_acsi_58

ADA Compliant

YES

Front Size

8" x 1-1/4"

Latchbolt Type

One Piece Anti-Friction Reversible Latch

Hub Material

Cold Forged Steel

Latchbolt Size

5/8" x 1"

Application

Fire Doors; Windstorm

Monitor Switch Rating

2A at 30VDC; 3A at 125VAC

Function Family

Fail Safe

Standards

UL Listed; California State Fire Marshall Approved; ANSI/BHMA A156.13 Series 1000 Operational Grade 1 and Security Grade 1 with All Standard Trims; UL and cUL Listed; ANSI/UL 10C, Positive Pressure Fire Test of Door Assemblies

Voltage

12 to 24VAC/VDC

Door Thickness

1-3/4 inch

Rose/Escutcheon Width

2-1/8 Inch

Product Projection

2-5/8 Inch

Electric Options

Request to Exit

Features

Simple User Selectable Fail Safe/Fail Secure Operation in Motor Controlled Locks; Continuous Duty Rated; Low Power Consumption; Interface With Life Safety Systems

Color Code

612/US10

Strike Type

Curved Lip

Backset

2-3/4 Inch

Warranty

10 Year Limited; 2 Year Limited Warranty on Electrified Locks

Rose/Escutcheon Length

2-1/8 Inch

Lever Size

5 Inch

Strike Lip

1-1/4 Inch

Finish Family

Satin Bronze

Product Overview
Sargent 8200 Series Office or Entry Mortise Lever Lock Modified with Fail Safe Operation (Power Lock), Authorized Egress (Request to Exit), Standard Control Locks Outside (Secure Side) Trim, LN Rose Design, B Lever Design, Motor Controlled, 10 Satin Bronze Finish, Less Cylinder
1500 SeriesElectric Mortise Lock

ACSI Series 1500 Electric Mortise Locks provide safety and security for stairtower doors or controlled areas where both locking and latching are required. The locks are available in motor-controlled or solenoid-controlled to allow remote electric locking or unlocking while conforming to life-safety codes.

Features:
  • UL Listed
  • California State Fire Marshall approved
  • Fail Safe (Power Lock)
  • - Outside trim is locked when power is applied and unlocked when power is removed (storeroom function when energized).
  • Lockset will unlock in the event of a power failure (passage function).
  • Fail Secure (Power Unlock)
  • - Outside trim is unlocked when power is applied and locked when power is removed. Lockset will lock in the event of a power failure.
  • Simple user selectable fail safe/fail secure operation in motor-controlled locks
  • Continuous duty rated
  • Low power consumption
  • 24VDC, 24VAC, 12VDC, or 12VAC operation
  • When key cylinders are provided in the locks, the latch bolt may be momentarily retracted with key even though electrically locked.
  • Note: Locks that are electrically unlocked may not be locked via the key cylinder.
  • Wide variety of monitoring options are available
  • Interface with life-safety systems
Sargent:
  • Models: 8237
  • Modifications: 1520M, 1510M, 1520C, 1510C, 1500
  • Options: AE2, LM, AM, LB, SM, DPS
  • Models: 8241
  • Modifications: 1520M, 1500
  • Options: AE2, DS
  • Models: 8225
  • Modifications: 1500
  • Options: AE2, DM
Specifications: 1510 - Fail Safe (Power Lock):
  • Outside trim (or both outside and inside trim depending on the lock function) is locked when power is applied and unlocked when power is removed. Lockset will unlock in the event of a power failure.
1520 - Fail Secure (Power Unlock):
  • Outside trim (or both outside and inside trim depending on the lock function) is unlocked when power is applied and locked when power is removed. Lockset will lock in the event of a power failure.
Key Function:
  • The latch bolt may be momentarily retracted with a key even though the lockset is electrically locked.
Electrical Specifications:
  • Voltage: 12-24V AC/DC (11V - 30V)
  • Current: 250mA MAX Inrush, 10mA MAX Holding
  • Non-polarized Leads
Switch Slider Settings:
  • Yellow: Fail Secure
  • Green: Fail Safe
2-Conductor Wire Run:
  • Distance 12V/24V: 125'/250'
  • Wire Gauge: 22
  • Distance 12V/24V: 200'/400'
  • Wire Gauge: 20
  • Distance 12V/24V: 300'/600'
  • Wire Gauge: 18
  • Distance 12V/24V: 500'/1000'
  • Wire Gauge: 16
  • Distance 12V/24V: 750'/1500'
  • Wire Gauge: 14
  • Distance 12V/24V: 1250'/2500'
  • Wire Gauge: 12
  • Note: Power must be applied to the lock after a switch slider setting change.