Roll over image to zoom in
Product Features
Product Overview
Related Videos
Reviews
Questions & Answers
Altronix AL-1012ULXPD16CB AL-1012 Hardwired Power Supply
Item #: AL-1012ULXPD16CB by Cansec Systems Ltd
30 Days Easy Return. We are the largest supplier of the most adaptable, personalized hardware in the industry. We work hard to ensure you're satisfied with our products.
Function
Power Supply
ADA Approved
False
Product Type
Access Control
Manufacturer Parent
Altronix
Enclosure Style
BC400 Enclosed
Output Type
Single Voltage
Battery Included
No
Class 2 Output Limited
Yes
Sub-Series
AL-1012ULXPD16CB
Fuse Size
2.5A
ADA Compliant
No
Operating Temperature
32 to 120°F
Number of Outputs
1-6
Visual Indicators
AC Input and DC Output Indicators
Standards
UL294 Listed; cUL Listed For CSA Standard C22.2 No.205-M1983; NFPA 72 Compliant
Rated Voltage
12VDC
Battery Type
Lead Acid; Gel
Features
Filtered, Electronic Regulated Output; Short Circuit, Thermal Overload Protection; Built-in Charger; Automatic Switch Over; Low Battery, Battery Presence, Notification Trigger and AC Fail Supervision
Fuse Type
PTC
Product Dimensions
15-1/2" x 12" x 4-1/2"
Battery Backup
YES
Input Voltage
115VAC
AL1012ULXPD16CB is a multi-output power supply/charger that converts a 115VAC, 60Hz input into sixteen (16) 12VDC Class 2 Rated power limited outputs.
Key Features:- Available with 1, 4, 8 or 16 outputs
- Fused or PTC ptotected outputs
- AC Fail;
- Battery Fail and Battery Presence.
- Built-in charger for sealed lead acid or gel type batteries
- Instantaneous transfer to stand-by batteries
- Short circuit and overload protection
- AC input and DC output options.
- UL Listed in the U.S. and Canada
- CSFM and MEA Approved
- Lifetime Warranty / Made in the U.S.A
- Voltage - 115VAC, 60Hz, 2.6A max.
- Fusing - 5A / 250V.
- Voltage - 12VDC.
- Current - 10A @ 12VDC continuous max.
- Protection - Fused 3.5A / PTC 2.5A.
- Other - Overvoltage protection. Filtered and regulated.
- Capacity - 12AH / 12VDC (1 within enclosure).
- 40 AH / 65 AH (requires separate enclosure).
- Type - Sealed lead acid or gel type.
- Failover - Upon AC loss, instantaneous.
- AC Failure - Form "C" contacts.
- Battery - Form "C" contacts.
- Input - 115VAC is present.
- DC - Output Powered.
- Battery - Discharged or not connected.
- UL - UL294 Access Control System Units.
- cUL - CSA C22.2 No.205 Signal Equipment.
- 15.5" x 12" x 4.5"
- (393.7mm x 304.8mm x 114.3mm)
- Product Weight - 8.85 lbs (4.0 kg)
- Shipping Weight - 11.15 lbs. (5.1 kg) ()
- Product Weight - 9.0 lbs. (4.1 kg)
- Shipping Weight - 11.3 lbs. (5.13 kg)
- Product Weight - 9.1 lbs. (4.13 kg)
- Shipping Weight - 11.4 lbs. (5.17 kg)
- Product Weight - 9.3 lbs. (4.22 kg)
- Shipping Weight - 11.6 lbs. (5.26 kg)
- Operating - 32°F to 120°F(120°F 0°C to 49°C)
- Storage - 4°F to 158°F (20°C to 70°C)
- 85% +/-5%
- 61 BTU/Hr.