Skip to main content
780-111 HD FFUL TIPIT 83" DBA 1PK REV S Dark Bronze Anodized

Roll over image to zoom in

Hager 008796Click To Copy 780-111 HD FFUL TIPIT 83" DBA 1PK REV S Dark Bronze Anodized

Item #: 008796 by Hager

See reviewsSee reviews
In Stock

$199.32

/each
SAVE UP TO 19.93

Buying in bulk


QTY
+
+ Add to Wishlist
Buy in Bulk & Save - See How Watch Now

Shop with Confidence

30 Days Easy Return. We are the largest supplier of the most adaptable, personalized hardware in the industry. We work hard to ensure you're satisfied with our products.

Features

Notes

EPD: Roton Continuous Hinges Environmental Product Declaration

Door Reinforcement

None required to 200 lbs. Heavier weight use 16-gauge channel.

Frame Reinforcement

None required to 200 lbs. Heavier weight use 16-gauge channel.

HINGE SIZE in. - CONTINUOUS

83

HINGE PACKING AND MISC. - CONTINUOUS

1 PACK CARTON w/ SCREWS AND w/ TIPIT

HINGE TYPE - CONTINUOUS

STANDARD

Length

79", 83", 85", 95", 119"

Fasteners

  • Standard: Dril-Kwik® – #12-24 X 11/16" Flat Head Screws
  • Optional: 1/2 Dril-Kwik® Screws, 1/2 wood Screws
  • Additional Options Available upon request

Material

Aluminum 6063-T6

HINGE FINISHES - ROTON

DBA - DARK BRONZE ETCH ANODIZE

Slug

/roton-continuous-geared-hinges/780-series-concealed-leaf-continuous-hinge/780-111-hd

Product Overview
  • Concealed Leaf
  • Heavy Duty

Clearance:
  • 5/16" (8 mm) hinge side
  • Plus standard lockside clearance

Electric Modifications:
  • Power Transfer Preparation (EPT 2) or (EPT 10),
  • Exposed Electric Contacts (E),
  • Exposed Electric Switches (E1S),
  • Electric Through-Wire (ETW),
  • Electric Monitoring (EMN),
  • Electric Through-Wire and Monitoring (ETM),
  • Removable Electric Through-Wire (RETW

Applications:
  • Lead lined model for hospital x-ray room doors with double row of fasteners to straddle lead (specify "LL")
  • Frame and door leaf alignment ribs for proper hinge and door location
  • 1/8" (3 mm) inset

Notes:
EPD: Roton Continuous Hinges Environmental Product Declaration
Features:
  • Standard duty for medium frequency doors. Heavy duty for high frequency doors or heavy, medium frequency doors.
  • Lead lined model for hospital x-ray room doors with double row of fasteners to straddle lead (Specify “LL”)
  • Frame and door leaf alignment ribs for proper hinge and door location
  • 1/8” (3 mm) inset

Finishes:
CLR, DBZ, BLK
Length Options:
Standard and Custom
Options:
  • Hospital Tip
  • TIPIT® (see Roton accessories)

Warranty:
All Roton products have a lifetime warranty. When ordering electric Roton, the electric portion of the hinge has a one-year warranty.