Eaton TRSGF20W GFCI Duplex Receptacle, 2 -Pole, 20 A, 125 V, Back, Side Wiring, NEMA: 5-20R, White
Item #: TRSGF20W by Cooper Wiring Devices
UPC #: 032664739989
30 Days Easy Return. We are the largest supplier of the most adaptable, personalized hardware in the industry. We work hard to ensure you're satisfied with our products.
- Performs periodic self-tests to ensure integrity of GFCI protection
- Large visual trip indicator light gives quick notification of a tripped or "end of life" condition
- Automatic grounding system eliminates need for bonding jumper in grounded metal enclosure, provides redundant measure of ground continuity where jumper is used
- Ground termination with back wire clamp provides secure wiring and reduces installation time
- Tamper-resistant shutters resist the insertion of foreign objects
- Line side terminals are backed out and staked for fast installation
- Horizontal test/reset button alignment provides larger unobstructed area
- Test and reset buttons are color matched to provide great aesthetics
- Tapered back wire openings handle multiple wire sizes and types for applications up to #10 AWG solid or stranded wire
- When downstream receptacles are wired from load side, a 20 A feed-through rating offers full protection
Department
ELECTRICAL
Shipping Dimensions
4.75x3.00x2.00
Mounting Type
Wall
Material
Nylon
Dimensions
4.2 in L x 1.68 in W x 1.27 in D
Application
For commercial, industrial and institutional uses areas like public bathrooms, breakrooms and food service areas
Color
White
Operating Temperature
-35 to 66 deg C
Wire Size
14 to 10 AWG
NEMA Configuration
5-20R
Number of Poles
2
Number of Wires
3
Frequency Rating
60 Hz
Nomenclature
TRSGF20W RCPT DPLX GFCI TR WH
Wiring Type
Back Side
Current Rating
20 A
Specifications:
Application: For commercial, industrial and institutional uses areas like public bathrooms, breakrooms and food service areas
Includes: Wallplate
GFCI receptacles are designed with the safety of the user in mind. In commercial and industrial areas like public bathrooms, breakrooms and food service areas, the NEC requires GFCI receptacles. Arrow Hart self-test GFCI receptacles are UL listed and fully compliant with all of the latest UL943 Class A GFCI and UL498 requirements. The self-test GFCIs conduct an automatic test periodically to ensure GFCI protection. The device will trip and will not reset if GFCI protection is not available. Additionally, GFCIs incorporate a safety lock-out function to protect against miswired line load connections and GFCI circuitry damage.