RECENTLY VIEWED
RECENTLY VIEWED
Don't have an Account? Create an Account
DK Hardware Professional Tax Exempt? Net 30? - DK Net Terms

Roll over image to zoom in
Product Features
Product Overview
Related Videos
Reviews
Questions & Answers
30 Days Easy Return. We are the largest supplier of the most adaptable, personalized hardware in the industry. We work hard to ensure you're satisfied with our products.
Wet Location Use
Yes
Insulation Thickness
15 mils
Flame Retardant
Yes
Returnable
Yes
Direct Burial
No
Wire Length
100 ft.
UL Listed
Yes
Conductor Gauge
14 Ga.
OM/RU
1/100
Sunlight/UV Resistant
Yes
Defective Code
A
Color
Silver
Jacket Material
Aluminum
Gauge/Conductors
14/2
Sub Brand
Armorlite
Indoor or Outdoor
Indoor and Outdoor
Cable or Wire Type
Copper
Number of Conductors
2
Amp Rating
15 amps
UOM
CL/100
Ground Material
Aluminum
Product Type
Cable
Conductor Material
Copper
Stranded or Solid
Solid
Number of Strands
1
Each Weight
0.156 LB
Nominal Total Weight
187 lb.
Velocity
X
Hazardous Material
No
Height
4.80
Length
11.50
Width
11.50
Country Origin Code
US
Application
For branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings
Type
Metal Clad
Operating Temperature
90 deg C
Sheath Diameter
0.447"
Nomenclature
55278323 14/2X100 AC CABLE
Conductor Insulation
THHN/THWN
Cable Size
14 AWG
Current Rating
15 A
Includes: Steel Armor
Constructed with soft-drawn copper, type THHN insulated conductors which are individually wrapped with a moisture-resistant, flame-retardant paper covering. Interlocking steel armor is applied over the assembly. A 16 AWG aluminum bond wire is placed inside the armor, runs longitudinally and is in intimate contact with the armor for its entire length. General applications include dry locations only, branch, feeder and service power distribution in commercial, industrial, institutional and multi-residential buildings, power, lighting, control and signal circuits, concealed or exposed installations, installed in cable tray and approved raceways, environmental air-handling spaces per NEC and under raised floors for information technology equipment conductors and cables per NEC 645.5(D) & 645.5(D)(2). 300.22(C), fished or embedded in plaster. Meets or exceeds the requirements of UL standard 4 for armored cable, UL standard 83, Federal Specification A-A59544 (formerly J-C-30B) and the National Electrical Code. Listed for use in UL 1, 2 and 3 hrs through-penetration firestop systems.