Skip to main content
Electric Mortise Lock Body FSE Fail Secure for 98/9975 Series, Reversible Handing, 24VDC, 630/US32D Satin Stainless Steel

Roll over image to zoom in

Von Duprin E7500-630 24VDC FSE Electric Mortise Lock Body FSE Fail Secure for 98/9975 Series, Reversible Handing, 24VDC, 630/US32D Satin Stainless Steel

Item #: E7500-630 24VDC FSE by Von Duprin

See reviewsSee reviews
See reviews summary
In Stock

$1,469.60

/each
SAVE UP TO 146.96
Buying in bulk
QUICK SHIPPING*Usually ships in 1 business dayIn stock: 30 units available
QTY
+
+ Add to Wishlist
Buy in Bulk & Save - See HowWatch Now

Shop with Confidence

30 Days Easy Return. We are the largest supplier of the most adaptable, personalized hardware in the industry. We work hard to ensure you're satisfied with our products.

Features

Alternate Part Number-1

154810

Handing

Field Reversible

Function

Electrified Mortise Body

Options

Electric Mortise Lock

Product Overview

Von Duprin E7500 Exit Device Mortise Lock

The electric mortise lock device has all the versatility and advantages of the standard mortise lock device, plus the advantage of being electrically controlled by a remote switching device, an access control system or an automatic fire alarm system. The device features the E7500 mortise lock. The E7500 controls the locking of the outside trim. When unlocked, the door remains latched, preserving the fire rating of the door and making it particularly useful where codes permit locking but require unlocking during a fire emergency. The outside trim cylinder retracts the latch bolt for mechanical override, night latch function. Only available with TP, K or L functions. The E7500 lock contains a SPDT signal to monitor the outside trim condition (locked or unlocked) and a second SPDT signal switch to monitor the latch bolt.

Optional Features:

  • Fail safe (locked when energized, unlocked when de-energized or during power failure).
    • Specify with suffix "FS."
  • Fail secure (unlocked when energized, locked when deenergized or during power failure).
    • Specify with suffix "FSE"
  • 24 VAC (with SO option)
  • 12 VDC
  • 12 VAC (with SO option)
  • Note: Some Fire codes will require "Fail Safe" (FS) operation for stairwell doors. Be sure to specify the correct operation for your application.

    Electrical Specifications:

  • Solenoid –
    • .60 AMPS @ 12VDC
    • .30 AMPS @ 24VDC
  • Each switch – Up to 2.0 AMPS @ 24VDC Maximum
  • Note: The E option does not include the power transfer from door to frame, the power supply or the control operator. (Refer to EPT-10 and PS902 or PS914 power supply)